DUPLICATOR              Model: RMC888

Operating Instruction

 

1.   PART NAME AND FUNCTIONS

¶ê¨¤¯x§Î¹Ï»¡¤å¦r: CONNECTOR¶ê¨¤¯x§Î¹Ï»¡¤å¦r: CONNECTOR
 

 

 

 

 

 

 

 

 

 

 

 

 

 


2. DUPLICATING

        Setting Procedure

Status Display

            Features

1.  Plug the adapter into any convenient

  AC outlet.

 0.0

frequency display

2. Press the 1 (SETTING) button

 r ¡V¡V 1

ready for reading¡Xwaiting for copy 1st code.

3. Code reading

place original transmitter in top of TEST AREA, press onto button 1. and holding the button till display shows done.

¶ê¨¤¯x§Î¹Ï»¡¤å¦r: 5 kinds display status after code reading

 

  done

 

 1.  A¡V10

for use our B type REMOCON

 2.  b¡V10

 3.  b¡V04

 4.  r e t y

Press the  1 (setting), and retry

 5.  E¡V10

code has not successful been read if flashed. repeat 2. or press 12 (RESTART) if required

4.

 r ¡V¡V 2

Waiting 2nd code enter

5. press onto button 2(original transmitter)

 ¡V¡V¡V¡V

Repeat above step 3. if required

6. wiring the to duplicator via cable connector, press 2 (DUP.)button.

 P¡V¡V¡V

Code is duplicating into REMOCON

LED display shows PA10, Pb10, Pb4, 10-04, 04-10, now the code has been duplicated into REMOCON successfully.

7. Tuning frequency

a.       press  1 (SETTING)

b.       place original transmitter in top of TEST AREA, press either button.

c.       place REMOCON in top of TEST AREA, press either button, then tunes frequency to be identified with original transmitter.

0.0

390.1

 

 

 

LED display shows frequency of original transmitter

For example 390.1MHz(please refer fig.1)

 

 

 

 

 

 

 

 


Fig. 1(RMC535)

 

3. VARIFYING(if required)

          Setting Procedure

 Status Display

            Features

1. press 3 (CHECK) button

 Chec

Enter into CHECK function

press the button 1 on the REMOCON

 ¡V¡V¡V¡V

code reading (press and holding the button till Display shows done)

 done

code reading completed

 L¡V¡V1

¡§button 1¡¨ confirmed

2.  press the button 2 on the transmitter

 ¡V¡V¡V¡V

code reading (press and holding the button till display shows done)

 done

code reading completed

 L¡V¡V2

confirm accurate ¡§button 2¡¨

3.  repeat step above if required

 no¡V¡V

code reading unable to confirm. But it doesn¡¦t mean the duplicating failure, particularly for b-04 .

repeat step 2. And 3.

 

 

 

 

 

 

 

 

 

 

 

4.    REDUPLICATING(requires REMOCON remote transmitter only)

Provide quantities capability

          Setting Procedure

 Status Display

            Features

1.  wiring the original transmitter to RMC888 via cable connector, press 13(REDUP.)

If above step appeared

 r¡V¡V¡V

code reading

 r A 1 0

code reading completed

Pb04 or Pb10

code reading completed

 E¡V¡V05

failed in code reading, please check cable connector or transmitter.

2.  wiring the REMOCON to Duplicator via cable connector, press 2 (DUP.)

 p¡V¡V¡V

code duplicating into REMOCON

 P A 1 0

duplicate completed for A type

Pb04, Pb10

duplicate completed for B type

 

 

ERROR READING

Status Display

Trouble shooting

E - 02

Failed in duplicating, please check if the connector fixed securely.

E - 03

Failed in duplicating, please check if the connector fixed securely.

E - 05

Failed in reduplicating, please check if the connector fixed securely.

E ¡V10

Reading failed, please re-operate.

E ¡V12

¡§Long Code¡¨ receives from original transmitter, unable to duplicate into button 5th and 10th.

E ¡V20

Can¡¦t not be duplicated by A type transmitter, please replace to B type.

*Above messages will be indicated as flash sequentially. Press 1 (SETTING) to keep operating.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.    DUAL FREQUENCY DUPLICATING( For Dual Frequency Transmitter only)

          Setting Procedure

 Status Display

            Features

1. Press 23(DUAL FREQ.) button

 r1 1 1

Dual frequency duplicating mode

2. Press 23(DUAL FREQ.) button

 r1 2 1

Dual frequency duplicating mode

3. Press 23(DUAL FREQ.) button

 r¡V¡V1

Single frequency duplicating mode

4. Following the above duplicating procedures.

 

Please refer above methods.

 

 

¶ê¨¤¯x§Î¹Ï»¡¤å¦r: Remote Buttons
 

 

 

 

 


¶ê¨¤¯x§Î¹Ï»¡¤å¦r: Code Reading                                                      r 1 2 1

¶ê¨¤¯x§Î¹Ï»¡¤å¦r: Position of Slide SW.
 

 

 

 


Fig. 2(RT-103)

 

6.    ADVANCE DUPLICATE FUNCTION FOR DUAL FREQUENCY

Provide only dual frequency transmitters(REMOCON)

Transmitter(REMOCON) Set SW.

Status Display

Transmitter(REMOCON) Remote Button

1st frequency

2nd frequency

 

 

SW-1

r 1 1 1

r 1 2 1

1

r 1 1 2

r 1 2 2

2

r 1 1 3

r 1 2 3

3

r 1 1 4

r 1 2 4

4

 

 

SW-2

r 2 2 1

r 2 1 1

1

r 2 2 2

r 2 1 2

2

r 2 2 3

r 2 1 3

3

r 2 2 4

r 2 1 4

4

CHART 1

 

 

 

While transmitter Set SW. setting on SW-1, both of them can transmit either 1st or 2nd frequency. Identically while setting on SW-2, both of them can transmit either 2nd or 1st frequency.

For example 1.: While duplicate two original transmitters(X+Y) into one dual frequency transmitter(REMOCON), when transmitter(REMOCON) setting on SW-1, please follow following duplicate procedures:

1.  Wiring the transmitter(REMOCON) to duplicator via cable connector. Press23 (SETTING) until LED display reads¡Kr 1 1 1.

2.  Press the first desire code duplicate button from original transmitter(X), LED display reads¡Kr 1 1 2.

3.  Press the second desire code duplicate button from original transmitter(X), LED display reads¡Kr 1 1 3.

4.  Press 23(DUAL FREQ.) button, LED display reads¡Kr 1 2 1.

5.  Press 1 (SETTING) button until LED display reads¡Kr 2 2 1.

6.  Press the first desire code duplicate button from original transmitter(Y), LED display reads¡Kr 2 2 2.

7.  Press the second desire code duplicate button from original transmitter(Y), LED display reads¡Kr 2 2 3.

8.  Press 2 (DUP.), LED display reads¡KP X X X, which means code duplicate completed.

 

For example 2.: While duplicate two original transmitters(X+Y) into one dual frequency transmitter(REMOCON), when transmitter(REMOCON) setting on SW-1

1st frequency¡XX original transmitter for button 1 and 2

2nd frequency¡XY original transmitter for button 3 and 4

please follow following duplicate procedures:

1.      Wiring the transmitter(REMOCON) to duplicator via cable connector. Press23 (SETTING) until LED display reads¡Kr 1 1 1.

2.      Press the first desire code duplicate button from original transmitter(X), LED display reads¡Kr 1 1 2.

3.      Press the second desire code duplicate button from original transmitter(X), LED display reads¡Kr 1 1 3.

4.      Press 23(DUAL FREQ.) button, LED display reads¡Kr 1 2 1.

5.      Press 1 (SETTING) button until LED display reads¡Kr 2 1 3.

6.      Press the first desire code duplicate button from original transmitter(Y), LED display reads¡Kr 2 1 4.

7.      Press the second desire code duplicate button from original transmitter(Y), LED display reads¡Kr 2 1 5.

8.      Press 2 (DUP.), LED display reads¡KP X X X, which means code duplicate completed.